Meeting Room Screen Size Calculator & Installation Guide

2026-11-20
AV sizing · meeting rooms · installation

Meeting Room Screen Size Calculator and Installation Guide: Sizing Interactive Meeting Room Screens People Actually Use

Two decisions ruin most meeting room display projects, and neither one happens in the negotiation. The first is a panel size chosen before anyone measured the room. The second is a panel delivered to a wall that nobody checked for load, power or cable path. Both end the same way: a screen that is too small to read from the back row, or too large for the front row to sit under, plus an installation bill that arrives twice. This guide replaces the guessing with numbers you can put straight into a quotation.

55–110 inone size ladder, no second supplier for the big room
350–500 nitsthe indoor band that keeps text readable without glare
20–50 ptsimultaneous touch for real workshop sessions
8-micbuilt-in array, so the room does not need a second audio box
meeting room screen size calculator smart board sizes interactive meeting room screens conference room touch screens boardroom display system
qtenboard 98 inch boardroom display system in executive meeting room

A 98-inch boardroom display system is the answer for a room of roughly 50–75 m² with the farthest seat around 8 m. The panel should look built into the room, not bolted onto it.

Skip the manual math

Our interactive flat panel size calculator takes room dimensions, user count and mounting height, cross-checks viewing distance against capacity, and returns a recommended size from 55 to 110 inches.

Run the size calculator

1. Start with the room, not the panel

Buyers generally discover the right size last. A 65-inch conference room touch screen in a 4 x 4 m huddle room is not a compromise; it is the correct specification, and it costs less than the 86-inch panel that gets returned two weeks later. Sizing starts from the room profile, and every profile changes what the room is actually asking of the screen.

Room profile Typical seats Põrandapind Farthest eye Primary job Starting size
Huddle / small collaboration4–610–16 m²2.5–4 mFast wireless casting, quick whiteboarding55-65 sees
Standard koosolekual8–1216–28 m²4-6 mHybrid meeting with slides plus annotation65–75 in
Large room / training room12–2028–45 m²6-8 mPresentation, workshop, group editing75-86 in
Boardroom / executive room10–1830–50 m²6–9 mDense financial decks, video with senior staff86-98 jass
Training hall / multi-use space20+45–80 m²8–11 mGroup work, multi-site sessions98–110 in

Starting sizes assume a 16:9 panel mounted at seated eye height. Confirm against the distance method in section 2 before you commit.

What each room profile is really asking for

  • Huddle rooms are sized for casting speed and desk-side writing, not for sightlines. If most of the meeting is a laptop screen mirrored for 20 minutes, a 55-inch interactive meeting room screen is genuinely sufficient, and the money saved belongs in the room booking and AV support budget.
  • Standard koosolekuumid are where annotation starts to matter. People present a deck, stop it, draw over a chart, save the annotated file and mail it out before the meeting ends. That workflow needs a panel large enough for two people to write at once without standing in front of each other.
  • Large and training rooms add a second problem: the back row. The panel is no longer a desk accessory, it is a presentation surface, and legibility at 7 m decides the size rather than taste.
  • Juhatusruumid weight appearance, cable management and video quality. A visible cable drop behind a 98-inch screen in an executive room is a design failure, not a technical detail.

Five numbers to record before you open a catalogue

  • Farthest eye to screen. A tape measure from the back wall seat cushion to the wall face, not the room length from the floor plan.
  • Nearest eye to screen. Usually the seat at the head of the table, two metres from the wall. This number decides whether a big panel is comfortable or not.
  • Usable wall width and height. Take the wall, then subtract the door swing, light switches, curtain track, air-conditioning unit and any glass partition frame.
  • Wall construction. Concrete or block, steel stud with one layer of board, or a glass partition. Each needs a different anchor strategy, and one of them may need a plywood backer installed before the panel arrives.
  • Power and data positions. Where the socket and network outlet sit today, and whether the cable can run behind the wall or must travel down a surface raceway.
The measurement that gets skipped: usable wall width. A 98-inch 16:9 panel is roughly 2.2 m wide. Put that on a 3 m wall and the whiteboard, the switch and the door swing have nowhere to go. Sales teams quote the screen; installers argue with the wall.
55 inch interactive meeting room screen in small huddle room

Sized to the farthest seat, not to the available wall: a 55-inch interactive screen in a 4.2 m huddle room leaves room for power, a light switch and a door swing.

2. The math behind any meeting room screen size calculator

Every sizing tool, including ours, reduces to one ratio: viewing distance divided by image height. The ratio changes with content. A financial model read line by line is not the same task as a video call, and the same room can justify two different panels depending on which task dominates.

2.1 Pick a multiplier, then convert to inches

Three multipliers cover almost every corporate room:

  • 3x height — critical viewing, dense text and detail work such as drawing review. This is the tightest ratio in common AV practice and the one used for quality grading.
  • 4x to 5x height — detail-heavy but not critical: spreadsheets, dashboards, annotated documents. On a 4K panel this range is comfortable because pixel density is high.
  • 6x height — the general readability rule for slide decks, video and mixed content. It is the default for meeting rooms that host more than one kind of session.
Two-step formula: required image height (m) = farthest viewing distance (m) divided by the multiplier. Then diagonal in inches ≈ 80 x height in metres for a 16:9 panel. The second step is just geometry: a 16:9 diagonal is 2.04 times the height, and 2.04 x 39.37 ≈ 80.

Worked through, it looks like this:

Farthest seat Slide-led (6x) Mixed, 4K (5x) Dense detail (4x) Practical pick
4 m53 in64 in80 in55 in huddle, 65 in if annotation is frequent
6 m80 in96 in120 in75 or 86 in; 86 in when the room runs weekly reviews
8 m107 in128 in160 in98 or 105 in; 110 in for boardrooms
10 m133 in160 in200 inBeyond a single panel: dual screen or a different display class

The practical pick assumes the room is used for a mix of content. If 80% of the meetings are dense documents, move one column to the right.

2.2 Cross-check against capacity and floor area

Distance alone can undersize a busy room. The second check is how many people have to share the screen and how much floor they occupy. Qtenboard publishes this ladder for its smart board sizes, and it is the table our calculator cross-checks against:

Panel size Tubade tüüp People Põrandapind Optimal viewing distance Max legible distance
55 inHuddle / small meeting room6–1012–18 m²1.5–3.5 m5.5 m
65 inVäike koosolekutuba10–1518–25 m²2.0–4.5 m6.5 m
75 inStandard meeting / training room15–2525–35 m²2.5–5.5 m7.5 m
86 seesSuur koosoleku-/koolitusruum25–3535–50 m²3.0–6.5 m8.6 m
98 inConference room / lecture room35–5550–75 m²3.5–8.0 m9.8 m
105 inLecture room / hall50–7575–100 m²4.0–9.0 m10.5 m
110 inAuditorium / multi-site hall70–120100–150 m²4.5–10.0 m11.0 m

Run both methods and take the larger result. When area suggests 86 inches and headcount suggests 75, the room is full and the 86 is the honest answer. If the budget only covers the smaller number, reduce the seat count rather than the screen.

2.3 4K changes how close people can sit, not how far they can read

A 4K interactive flat panel resolves fine detail at closer distances than a 1080p panel, which is why 86-inch screens now work in rooms that once needed 98. What 4K does not fix is angular size: a line of 12 pt text subtends the same angle whether the panel has four times the pixels or not. Resolution buys comfort at the near seat and sharpness in screenshots; it does not extend the back row. Treat any salesman who claims otherwise as a warning sign.

2.4 Two traps: the nearest seat and the aspect ratio

  • The nearest seat. Minimum comfortable distance is about twice the image height. An 86-inch panel is 1.07 m tall, so nobody should be closer than roughly 2.1 m. Fill a room with a 110-inch panel and the person at the head of the table sits 1.8 m away, looking up at a wall of light. Fix it by moving the table back, raising the panel to a centre line of 1.15–1.30 m, or stepping down a size.
  • The aspect ratio. Older conference displays sometimes use 16:10, which is taller for the same diagonal. Calculations run on height, so a 16:10 panel delivers more image height than the label suggests. Always use the mechanical drawing rather than the diagonal when the panel is not 16:9.

2.5 Brightness: why 350–500 nits is the right target indoors

Meeting rooms are not shop windows. A commercial panel rated 350 nits with a good anti-glare surface reads cleanly under normal office lighting; 400 to 450 nits covers rooms with a window wall or dense ceiling fixtures; 500 nits is the top of the useful range for a bright boardroom. Panels advertised at 700 nits and above are usually fighting direct sunlight that a meeting room should not have in the first place, and the extra brightness tends to cost contrast, uniformity and eye comfort during a two-hour session. For any interactive meeting room screen used eight hours a day, stable brightness across the panel matters more than the peak number on the datasheet.

Send the room, get a size and a mounting plan

Room length, width, seat count and one photo of the wall are enough for our engineers to return a recommended model, a mounting height and a cable route.

Request a sizing review

3. Mounting: wall, mobile stand, recessed, or two screens

The mounting decision follows the room, not the panel. Four options cover corporate work, and each one carries a different risk that has to be resolved before purchase rather than after delivery.

3.1 Wall mount: the default, and the one that fails on height

Wall mounting is correct for any room with a fixed screen wall. Three details decide whether it works:

  • Vertical position. Set the image centre line 1.15–1.30 m above the floor for seated rooms. On an 86-inch panel that puts the bottom edge around 0.7 m and the top at roughly 1.8 m, which keeps the whole image inside a 15° upward cone from the back row. Screens installed at standing height force delegates to tilt their heads for an hour.
  • Substrate and load. Concrete and block take mechanical anchors. Steel stud needs the bracket bridged across at least two studs, or a plywood backer fitted during fit-out. A glass partition needs a freestanding frame, not a bracket. Confirm the unit and package weight from the model datasheet before ordering hardware, because an 86-inch panel and its crate need two installers and a lift, not one person and a ladder.
  • Service access. Keep 40–60 mm of standoff for airflow, and mount so that the side or bottom port strip stays reachable. A panel installed flush to a shelf unit with the ports behind a fixed cabinet turns every firmware update into a removal job.

3.2 Mobile stand: flexibility with a cable problem attached

Mobile stands suit multi-purpose rooms, temporary project spaces and training floors where one panel serves four rooms. The panel becomes a shared asset, which is exactly the economics many buyers want.

The complications are physical. Check the door width and the floor transition before the stand arrives, because a wheeled 86-inch unit on a 1.5 cm threshold is a two-person job every time it moves. Plan power and data as a route rather than a plug: a floor box at the front of the room, or a battery-free layout with a short trailing lead and a wall socket positioned where the stand parks. Cable trays on the stand hide the mess; a loose HDMI cable on the floor does not. Where rooms turn over frequently, a rolling stand paired with wireless casting removes most of the cabling problem at once.

interactive meeting room screen on mobile stand in training room

A mobile stand turns one 86-inch panel into a shared asset for four training rooms — provided the doors, thresholds and parking socket are checked first.

3.3 Recessed mount: the boardroom finish, at fit-out prices

Recessing the panel into a feature wall gives the cleanest boardroom result: the screen reads as part of the architecture, the cabling disappears, and the front face sits flush with the joinery. It is also the option most likely to be specified too late.

A recessed installation needs a cavity deep enough for the panel plus airflow, a service hatch for port access and firmware work, and conduit that reaches the cavity before the wall closes. Never seal the cavity: a fully enclosed panel runs hot, and heat is the quiet killer of LCD life. If the room is already finished, recessing means opening the wall, and that cost belongs in the project budget rather than in a change order.

recessed boardroom display system with wiring and service panel

Recessed boardroom display with a service panel below the screen: the hatch is what makes a flush finish maintainable rather than permanent.

3.4 One screen or two: when a boardroom display system needs a pair

Dual screens are not a size upgrade; they are a task split. Two 86-inch panels let a hybrid meeting show remote participants on one screen and content on the other, so nobody has to choose between watching faces and reading a spreadsheet. They also fix the geometry problem in rooms deeper than about 9 m, where a single panel large enough for the back row would be uncomfortable for the front row.

Dual installations carry their own coordination cost: a matched pair of panels, a bracket or rail system that keeps them level, one cable plan, and a decision about whether they run as extended desktop or mirrored. Decide that before the wall is built, because retrofitting a second screen means reopening the cable route.

dual screen boardroom display system for video conferencing

Dual 86-inch panels in a boardroom: remote participants on the left, content on the right. The second screen is a task decision, not a size decision.

3.5 Who actually does the installation

Self-install

Workable for 55 to 75-inch panels on a sound wall with an existing socket. Budget half a day, two people and a wall scanner. Not workable above 86 inches without lifting equipment.

Local AV integrator

The normal route for boardrooms and multi-room rollouts. They own the wall survey, the bracket, the cable route and the commissioning document. Ask for the survey photos, not just the invoice.

Factory-supported delivery

Qtenboard supplies mounting drawings, port maps, firmware baseline and DMS enrolment guidance with the shipment, so the integrator installs to a known reference instead of improvising on site.

Whoever signs the handover

Name one person accountable for acceptance. Projects with three stakeholders and no signatory are the ones that reopen the wall twice.

4. Site readiness: twelve checks before the crate arrives

Every item below has stopped a delivery at least once in real projects. Run them as a checklist with the facilities team, not as a conversation in the corridor.

  • Dedicated power circuit at the screen wall, socket not hidden behind the panel
  • Wired network point within reach, or a documented Wi-Fi plan for the room
  • Cable route confirmed: in-wall conduit, ceiling void or surface raceway
  • One spare pull wire left in the conduit for the next device
  • Interface list matched to the panel: HDMI in and out, USB, Type-C, DP, VGA, RJ45, RS232
  • Ambient light checked at the screen wall, not at the door
  • Air-conditioning diffuser not blowing onto the top of the panel
  • Wall obstructions mapped: switches, sockets, curtain track, door swing
  • Freight path measured: door width, lift car, stair turn, packaging dimensions
  • Floor and joinery protected along the carry route
  • Working hours and building permits agreed for the install day
  • Lead time for a replacement panel and the swap procedure written down

Two of these deserve their own paragraph. Võimsus: is the one that most often fails late: a socket installed at 1.1 m behind a wall-mounted panel is unreachable once the bracket is on, and a room with no spare circuit cannot take a second screen later. Put the socket to the side of the panel footprint, or bring it into the recessed cavity with the service hatch. Freight is the one that fails on the morning of delivery: packaging for an 86-inch panel is close to 2.2 m long, and a 110-inch crate does not fit a standard passenger lift. Measure the route before the order ships, and price the crane or the extra crew into the project rather than discovering it at the loading dock.

installer measuring wall distance for conference room touch screen

Ten minutes with a laser measure at the screen wall replaces an afternoon of rework. Record wall width, floor height and the nearest and farthest eye positions.

5. Commissioning and handover: the part that decides adoption

A meeting room screen that nobody uses was usually commissioned in five minutes. Handover should be a documented sequence, and it should end with a named person able to run the room without calling IT.

5.1 Visual acceptance

Stand at the farthest seat and read a document with 12 pt text. If it is not comfortable, the size or the mounting height is wrong and no amount of software tuning will fix it. Then check level, check for flex when you press the corners, and check that ambient reflections from windows do not land on the working area of the screen at the time of day the room is busiest.

5.2 Touch, cast and video

  • Puudutus: test all four corners and the centre with a stylus and with a finger. Multi-touch should register 20 points or more, palm rejection should ignore a resting hand, and the eraser should work without opening a menu.
  • Casting: test one Windows laptop, one macOS laptop, one iPhone and one Android phone. Record the success rate per device type; a room that casts on the second attempt every time trains people to avoid it.
  • Video and audio: walk the room while talking. The built-in 8-mic array should hold a normal speaking voice from the far end of the table without gain artefacts, and the camera — an optional fitment on the Qtenboard series — should frame the seats that actually speak, not just the head of the table.

5.3 Management and the acceptance document

Enrol the panel in device management before the room goes live. From a central console you can see online status, push settings, schedule updates and confirm the firmware baseline across every room. Write the baseline version, the room name, the network settings and the support contact into a one-page handover sheet, and run a 20-minute training session for the room owner covering cast, write, save and shut down. That page is what stops the second visit.

6. The rework list: seven mistakes and what they cost

What goes wrong Algpõhjus What the fix involves
Screen mounted too highHeight set for standing presentationRe-anchor the bracket, patch and repaint the wall; two visits minimum
Bracket under-ratedHardware bought for a smaller modelNew bracket, new anchors, and a structural check on the stud wall
No cable pre-runNetwork outlet on the opposite wallSurface raceway or an in-wall run; finishes disturbed either way
Only the far seat consideredSize chosen from room length alonePanel exchange, re-delivery and re-installation on both ends
Recessed with no service hatchJoinery closed before commissioningCut the wall, add a hatch, refinish; the panel comes out first
Socket behind the panelPower position set from the floor planRelocate the circuit, or accept an inaccessible outlet forever
Crate will not fit the liftFreight path never measuredCrane hire, stair carry with extra crew, or a damaged panel claim

Every row on this list is cheaper to prevent than to fix, and none of them is a product fault. They are survey failures. That is why a sizing exercise without a site check is only half a specification.

7. Why Qtenboard for meeting room rollouts

Qtenboard has manufactured interactive displays since 2005, from a 330,000 m² production base in Shenzhen and Guangzhou, with more than 1,000 staff and shipments to over 100 countries. That matters to a buyer in a specific way: the same factory supplies the 55-inch huddle panel and the 110-inch boardroom panel, so a multi-room programme runs on one size ladder, one firmware family and one support channel instead of three vendor relationships.

Parameeter Qtenboard interactive flat panel (meeting series)
Size ladder55 / 65 / 75 / 86 / 98 / 105 / 110 in
Lahutamine3840 x 2160, 4K UHD
Heledus350–500 cd/m² by model and size, indoor specification
Contrast / viewing angle4000:1 typical, 178° horizontal and vertical
PuudusInfrared with zero-gap bonding, 20–50 simultaneous points, pen and finger, palm rejection
Glass and panel lifeAnti-glare tempered glass, 4 mm; 60,000 hours typical LCD life
OperatsioonisüsteemAndroid 14 (up to Android 16 by platform), optional Windows 10/11 via OPS module
PlatvormMT9679 / RK3576 / 311D2 / V100 / RK3588 options, 4+32 GB to 16+256 GB
Kaamera ja heliCamera optional (8 MP / 48 MP / 4K), 8-mic array built in
ÜhendusHDMI in and out, USB 3.0 / 2.0, USB-B, Type-C, DP, VGA, RJ45 in and out, RS232, TF card, OPS slot; Wi-Fi 6 dual band, Bluetooth 5.2
JuhtkondDMS console for fleet status, settings push and update scheduling
Compliance and supplyCE, FCC and RoHS documentation, ISO 9001 factory system, Google EDLA certification on the EDLA series; OEM / ODM / CKD / SKD programmes

For a specification document, the practical links are the interactive whiteboard product overview, full product index including the rolling mobile cart for 55–86-inch panels, and the IFP size selection calculator for the room-by-room numbers. Buyers comparing room types before committing will also find the conference room setup and buying guide useful, and the presentation-by-presentation selection page covers the case where one panel serves sales pitches rather than internal reviews.

“If the room cannot read it from the back row, the panel is the wrong size — regardless of what the invoice says.”

8. Project profiles

Three deployment patterns repeat across corporate rollouts. Details are generalised at the client’s request; the configuration and the failure modes are what matter.

Corporate HQ · 12 rooms

One ladder instead of three purchases

A headquarters refresh needed four large rooms, six standard rooms and two huddle rooms on a single support contract. The programme used 86-inch panels for the boardroom and training hall, 75-inch for the review rooms and 65-inch for the huddle spaces, all on the same firmware family and enrolled in one management console. The saving came from operations rather than unit price: one spare panel covered every room, and one image update ran across the estate overnight.

Sizing basis: farthest seat 6.0–8.2 m · dual-screen split for the two hybrid rooms · wall survey completed before fit-out

Training centre · shared panels

Four rooms, two panels, one timetable

A training provider with four teaching rooms and a fixed capital plan bought two 86-inch panels on rolling stands rather than four wall-mounted screens. Rooms were booked against the panels, and wireless casting removed most of the cabling work. The risk was physical, not technical: the stand had to clear a 90 cm door and a lift threshold, and the parking sockets had to sit where the stand actually stopped, not where the electrician assumed it would.

Sizing basis: farthest seat 6.5 m · mobile stand with cable tray · door and threshold checked pre-order

Boardroom · recessed

The flush finish that still opens

An executive floor wanted the panel to disappear into a walnut feature wall. The installation used a recessed cavity with a service panel below the screen, conduit to a floor box, and a 50 mm airflow gap behind the unit. The detail that saved the project was the hatch: six months later a firmware roll-out and a port change happened without touching the joinery.

Sizing basis: farthest seat 7.5 m, dense financial content · 98-inch panel · centre line 1.25 m

9. FAQ

What size interactive screen for a 4 x 4 m meeting room?

A 55-inch panel is correct if the farthest seat is around 3.5 m, and a 65-inch is the safer pick if four people write at the same time or the room is used for weekly client calls. Both sit well inside the 6x height rule, and both leave wall space for a whiteboard and a switch.

My room is 8 m long. Which smart board size do I need?

At 8 m to the farthest eye, the general readability rule points to roughly 98 inches, and a 105-inch panel is the safer choice if the content is dense. If the room is deeper than 9 m, a single panel large enough for the back row becomes uncomfortable for the front row, and a dual-screen layout is the better answer.

Does 4K let me use a smaller panel?

It lets people sit closer without seeing pixels, so it improves the near-seat experience and screenshot quality. It does not extend how far a line of small text stays readable. Size the panel on height and distance, then choose 4K for sharpness.

How high should the screen be mounted?

Image centre line at 1.15–1.30 m above the floor for seated rooms. That keeps the whole image inside a 15° upward viewing angle from the back row. If the screen must go higher, tilt is a partial fix and a smaller panel is the real one.

Do I need 400 nits or more for a meeting room?

350 nits with anti-glare glass handles a normal office room. Move to 400–450 nits for a room with a window wall or dense ceiling fixtures, and 500 nits for a bright boardroom. Beyond that you are paying for brightness the room does not need, usually at the cost of contrast and comfort.

Is a camera and microphone array worth adding?

For any room that hosts hybrid meetings, yes — it removes the separate video bar and the cable that goes with it. On the Qtenboard series the camera is optional (8 MP, 48 MP or 4K) and the 8-mic array is built in, so the decision is about video quality and framing rather than whether audio exists at all.

Can I install a 98-inch panel myself?

No, not safely. A unit of that size needs two trained installers, a lift or a scissor platform, mechanical anchors matched to the substrate, and a wall survey. The saving on labour is smaller than the cost of a dropped panel or a bracket that lets go at the top corners.

What lead time should I plan for a multi-room rollout?

Plan in two stages: standard configurations are quoted within one business day, and the schedule is set by panel production plus freight plus the site survey, which is usually the slowest part. Get the wall survey booked the week the purchase order is raised, not the week the panels arrive.

Give us the room. We will give you the size, the height and the cable route.

Send room dimensions, seat count and a photo of the screen wall. Our engineers return a recommended model from the 55–110 inch ladder, a mounting height, a port list and a quotation for the project quantity.

Start a project inquiry

Reviewed by the Qtenboard AV engineering team, Shenzhen

Sizing rules and mounting guidance in this guide come from corporate meeting room deliveries and factory production data across 55–110 inch interactive flat panels. Room-specific recommendations should be confirmed against a wall survey and the model’s mechanical drawing.

Product figures reflect published Qtenboard specifications for the meeting series: 4K UHD resolution, 350–500 cd/m² brightness by model, infrared zero-gap touch with 20–50 points, Android 14 with optional Windows OPS, optional camera and 8-mic array. Distance and capacity bands follow the Qtenboard interactive flat panel size calculator. Sizes available: 55, 65, 75, 86, 98, 105 and 110 inches.


Qtenboard Queenie Wang

Queenie Wangi

Tegevjuht | Interaktiivne ekraani ja koostöö lahendusekspert

Olen Qtenboardi asutaja, tuues üle 17-aastase praktilise oskusteadmisega puute kuvatööstusesse. Võttes arvesse ülemaailmse juhtimise perspektiivi, mis on saavutatud minu EMBA uuringud ShenZheni ülikoolis, Ma juhin Tootmisvõime jääb tööstuse esirinnas.

Qtenboardi juhina olen spetsialiseerunud kohandatud OEM/ODM-lahenduste pakkumisele interaktiivsetele valgeplaatidele, LCD video seinad, digitaalsed signaalid ja tööstusliku kvaliteediga puuteterminalid. Toetas meie 330.000 m nüüdisaegse tööstuspargi Shenzhenis, säilitame täispuhastuse kontrolli tööstusdisaini, täpsuse tootmise, ja range jõudluse testimine.

Peaaegu kaks aastakümne pikkune projektikogemus kasutatakse Qtenboardi ekraani lahendusi nüüd rohkem kui 120 riigis ja piirkonnas, teenis usaldust üle 15000 ettevõtluskliendi üle maailma. Kui otsite tundlik partner sügava tootmise aluse oma kohandatud touch kuva projekte, Minu meeskonnaga oleme valmis toetama teie nägemust professionaalselt.